diff --git a/cpdctrl_gui/resources/troubleshooting.md b/cpdctrl_gui/resources/troubleshooting.md new file mode 100644 index 0000000..8bcf000 --- /dev/null +++ b/cpdctrl_gui/resources/troubleshooting.md @@ -0,0 +1,6 @@ +## Troubleshooting +### 1) The LED does not work +1) Make sure the Thorlabs LED is plugged in, turned on (turn the dial to a non-zero value) and that the switch is in the **TRIG**er position +2) Reset the Arduino by pressing the white button on the top and restart the program +3) Unplug and replug the Arduino and restart the program +4) Re-upload the code (see section "Arduino Code") \ No newline at end of file diff --git a/cpdctrl_gui/resources/user_guide.md b/cpdctrl_gui/resources/user_guide.md new file mode 100644 index 0000000..7160a4c --- /dev/null +++ b/cpdctrl_gui/resources/user_guide.md @@ -0,0 +1,54 @@ +# CPD User Guide +## Changing the sample +1. Stop the turbopump: + 1. Press the stop button on the control panel + 2. Close the valve between pump and chamber (on top of the turbo pump), by screwing it into the pump +2. Ventilate the chamber + 1. Open the gate valve + 2. Carefully open the needle valve (usually less than 1/8 turn) + 3. When the chamber can be moved, close both valves again +3. Take off the chamber + 1. Make some space to put the chamber (mind the grease on the bottom edge) + 2. Carefully lift the chamber. Good places to grab it are the tubing on the left and the right bottom edge. + ***Caution***: The tube connecting the chamber with the pump will exert a force to the right! + **Make sure you do not crash the chamber into the sample tray!** +4. Move the sample away from the gold mesh + 1. Move the tray fully down by turning the upper micrometer screw *counterclockwise* + 2. Move the tray fully to the left using the larger micrometer screw + 3. Loosen the screw on the clamp holding the sample in place and remove the sample +5. Prepare the new sample + 1. Put the sample on the tray and place the clamp on it. + 2. Tighten the clamp screw (you might need to grab the nut on the bottom side) + 3. Move the tray in x-position using the large micrometer screw. + The gold mesh should be well aligned with the sample surface + 4. Carefully move the tray up by turning the small micrometer screw *clockwise*. + Leave about half a millimeter of space between the sample and the gold mesh + **Do not crash the sample into the gold mesh!** +6. Put the chamber back on + 1. Put the chamber back on and align it on the two posts on the bottom and right + 2. Check the backside to make sure that no cables are sticking out +7. Vacuum the chamber + 1. Make sure the nitrogen venting valves are closed + 2. **Make sure the turbopump is not spinning anymore** + 3. When the turbopump has fully stopped, very slowly open the valve on top of the pump + 4. Fully open the valve **TODO: hier noch irgendwelche checks?** + 5. **Wait** until the vacuum is in the lower $10^{-2}$ range (read the value from the sensor attached to the turbopump) + 6. Only when this target pressure is reached, turn on the turbopump (control panel on top) + 7. Wait until the desired vacuum for measurement is reached (usually $10^{-5}$) + - $10^{-4}$: **TODO** + - $10^{-5}$: **TODO** + - $10^{-6}$: after 1-2 days + + If the pressure does not drop enough: Use isopropanol to inspect for leaks + +## CPD Controller Calibration +**TODO** + +This process is not always necessary. +1. Set CPD Controller to Manual, Offset=Gold Work Function, Filter off (so you can see what happens immediately), Oscillator to ~2 +2. Move the micrometer screw close until a signal appears +3. Set Automatic offset so that the output is 0V +Calibration: Fresh graphite probe + +## cpdctrl-gui Software +**TODO**